检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马淑栋[1] 张入通[1] 郭彦斌[1] 周媛[1] 李学先[1] 陈岩[1]
出 处:《原子能科学技术》2012年第3期364-369,共6页Atomic Energy Science and Technology
基 金:国家数控机床重大专项资助项目(2009ZX04014-091)
摘 要:本文研究12MeV无损检测用电子直线加速器靶的验证计算。首先通过具体分析无损检测用电子直线加速器中电子与靶相互作用的物理机理,由经验公式计算推得最佳靶厚及对应的靶产额、剂量率分布、X光子的转换效率;其次运用MCNP对常用靶材W、Au、Ta产生的X光子剂量率分布和转换效率进行对比计算,确定最佳靶材及靶厚;最后与实验结果对比,验证了靶计算过程的正确性。The confirm calculation of 12 MeV non-destructive testing (NDT) electron linear accelerator (LINAC) target was studied. Firstly, the most optimal target thick- ness and related photon dose yield, distributions of dose rate, and related photon con- version efficiencies were got by calculation with specific analysis of the physical mecha- nism of the interactions between the beam and target; Secondly, the photon dose rate distribution, converter efficiencies, and thickness of various kinds of targets, such as W, Au, Ta, etc. were verified by MCNP simulation and the most optimal target was got using the MCNP code; Lastly, the calculation results of theory and MCNP were compared to confirm the validity of target calculation.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.225.144