检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:罗伟锋[1]
机构地区:[1]煤炭科学研究总院杭州环保研究院,浙江杭州311201
出 处:《能源环境保护》2012年第1期39-41,共3页Energy Environmental Protection
摘 要:本文对电镀废水经物化预处理--反渗透回收处理后的膜浓废水作为对象,将微电解--芬顿破反应处理方法作为破络合反应,对重金属、COD的去除方法进行了研究,确定了pH4,双氧水加药量3‰,反应时间60 min,是比较好的破络合反应条件;经破络处理后的废水中,进行pH调节后,投加硫化钠浓度50 mg/L,重金属捕捉剂10 mg/L可以将反渗透膜浓水中较低浓度的重金属及COD处理至国家排放标准。Abstract: In this paper, the electroplating wastewater treated by physical-chemical pretreat- ment and reverse osmosis (RO) processing. The heavy metals and COD removal method of RO concentrated water which broken-complexation by micro-electrolysis fenton reaction has been researched. The results showed that the best conditions of broken-complexation are pH 4, hy- drogen peroxide dosage 3 %o and the reaction time 60 min. After the processing of broken- eomplexation reaction, pH adjusting and dosing 50 mg/L sodium sulfide and 10 mg/L heavy metal capture agent, the RO concentrated water which has low concentration of heavy metals and COD reaches the national emission standard
分 类 号:X703[环境科学与工程—环境工程]