机构地区:[1]School of Textile,Zhejiang Industry Polytechnic College [2]Key Laboratory of Macromolecule Synthesis and Functionalization of Ministry of Education,Department of Polymer Science and Engneering,Zhejiang University
出 处:《Journal of Wuhan University of Technology(Materials Science)》2012年第2期301-309,共9页武汉理工大学学报(材料科学英文版)
基 金:Funded by the Foundation for University Young Key Teacher by Zhejiang Province
摘 要:Membrane surfaces modified with poly(N-vinyl-2-pyrrolidone) (PNVP) can be endowed with hydrophilicity, biocompatibility and functionality. In this work, atmospheric pressure dielectric barrier discharge plasma graft polymerization of N-vinyl-2-pyrrolidone (NVP) onto polypropylene (PP) microporous membrane surface was studied. The experimental results reveal that plasma treatment conditions, such as discharge power, treatment time and adsorbed NVP amount, have remarkable effects on the grafting degree of NVP. Structural and morphological changes on the membrane surfaces were characterized by attenuated total reflection-Fourier transform infrared spectroscopy (FT-IR/ATR), X-ray photoelectron spectroscope (XPS) and field emission scanning electron microscopy (FE-SEM). Water contact angles of the membrane surfaces were also measured by the sessile drop method. Water contact angles on the membrane surfaces decrease with the increase of NVP grafting degree, which indicates an enhanced hydrophilicity for the modified membranes. The effects of grafting degrees on pure water fluxes were also measured. It is shown that pure water fluxes increase with grafting degree firstly and then decrease adversely. Finally, filtration of bovine serum albumin (BSA) solution and platelets adhesion of the PNVP modified membranes show good protein resistance and potential biocompatibility due to the enhancement of surface hydrophilicity.Membrane surfaces modified with poly(N-vinyl-2-pyrrolidone) (PNVP) can be endowed with hydrophilicity, biocompatibility and functionality. In this work, atmospheric pressure dielectric barrier discharge plasma graft polymerization of N-vinyl-2-pyrrolidone (NVP) onto polypropylene (PP) microporous membrane surface was studied. The experimental results reveal that plasma treatment conditions, such as discharge power, treatment time and adsorbed NVP amount, have remarkable effects on the grafting degree of NVP. Structural and morphological changes on the membrane surfaces were characterized by attenuated total reflection-Fourier transform infrared spectroscopy (FT-IR/ATR), X-ray photoelectron spectroscope (XPS) and field emission scanning electron microscopy (FE-SEM). Water contact angles of the membrane surfaces were also measured by the sessile drop method. Water contact angles on the membrane surfaces decrease with the increase of NVP grafting degree, which indicates an enhanced hydrophilicity for the modified membranes. The effects of grafting degrees on pure water fluxes were also measured. It is shown that pure water fluxes increase with grafting degree firstly and then decrease adversely. Finally, filtration of bovine serum albumin (BSA) solution and platelets adhesion of the PNVP modified membranes show good protein resistance and potential biocompatibility due to the enhancement of surface hydrophilicity.
关 键 词:polypropylene microporous membrane NVP atmospheric-pressure plasma GRAFT ANTIFOULING
分 类 号:TB383.2[一般工业技术—材料科学与工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...