机构地区:[1]School of Chemistry and Chemical Engineering,Changzhou University,Changzhou 213164,China [2]Zhe Jiang Academy of Traditional Chinese Medicine,Hangzhou 310007,China [3]College of Biology and Environment Engineering,Zhejiang Shuren University,Hangzhou 310015,China [4]Department of Chemistry,Xixi Campus,Zhejiang University,Hangzhou 310028,China
出 处:《Chinese Chemical Letters》2012年第3期335-338,共4页中国化学快报(英文版)
基 金:supported by the National Natural Science Foundation of China(Nos20775070,and 20911140271);the Natural Science Foundation of Zhejiang Province(NoR4080124)
摘 要:A rapid and practical method for direct detection of lisinopril in anion exchange chromatography(AEC) has been developed with integrated pulsed amperometric detection(IPAD).Dionex AS 18(250 mm×2 mm) and AG 18(50 mm×2 mm) columns and 40 mmol/L NaOH solution were used for separation.Multi-step potential waveform parameters were optimized to maximize the signal-to-noise ratio(S/N).Utilizing the optimized waveform,the repeatability(intra-day) precision and intermediate(inter-day) precision were obtained with relative standard deviation(RSD) of 0.74,0.93,respectively.The limit of quantification(LOQ) and limit of detection(LOD) were found to be 0.37,0.12ng/mL,respectively,with the correlation coefficient of 0.9998 over concentration range 0.01-1μg/mL.The present method was successfully applied to the determination of lisinopril in human plasma.The recoveries of plasma sample spiked by 0.2μg/mL,0.8μg/mL lisinopril were 98.31-103.23%with RSD of 1.41%, 0.61%,respectively.A rapid and practical method for direct detection of lisinopril in anion exchange chromatography(AEC) has been developed with integrated pulsed amperometric detection(IPAD).Dionex AS 18(250 mm×2 mm) and AG 18(50 mm×2 mm) columns and 40 mmol/L NaOH solution were used for separation.Multi-step potential waveform parameters were optimized to maximize the signal-to-noise ratio(S/N).Utilizing the optimized waveform,the repeatability(intra-day) precision and intermediate(inter-day) precision were obtained with relative standard deviation(RSD) of 0.74,0.93,respectively.The limit of quantification(LOQ) and limit of detection(LOD) were found to be 0.37,0.12ng/mL,respectively,with the correlation coefficient of 0.9998 over concentration range 0.01-1μg/mL.The present method was successfully applied to the determination of lisinopril in human plasma.The recoveries of plasma sample spiked by 0.2μg/mL,0.8μg/mL lisinopril were 98.31-103.23%with RSD of 1.41%, 0.61%,respectively.
关 键 词:LISINOPRIL Integrated pulsed amperometry Anion exchange chromatography Angiotensin converting enzyme inhibitor PLASMA
分 类 号:TF816[冶金工程—有色金属冶金] TH832[机械工程—仪器科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...