检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]江苏省农业科学院粮食作物研究所江苏省农业种质资源保护与利用中心,南京210014
出 处:《现代科学仪器》2012年第1期157-158,共2页Modern Scientific Instruments
摘 要:电磁力平衡式传感器是利用电磁力与负荷相平衡的原理工作,结构复杂但精度很高,常用于高精度电子天平。电磁力平衡式传感器由于材料和结构上的原因,线圈和磁钢之间的间隙很小。当人员操作不当或元器件损坏时,会产生各种故障。本文介绍了电磁力平衡式传感器和电子天平的工作原理,分析显示"ERR—54"故障代码的原因,讲述故障的修理过程以及修复后的校准。Electromagnetic force-balance sensor functions on the principle of the balance between electromagnetic force and the load.Featuring complex structure and high precision,it is usually used on high-precision electronic balance.The gap between the coil and magnet steel is very narrow for the reason of the material and structure adopted by the electromagnetic force-balance sensor.It will run into many kinds of faults due to improper operation or component damage.This paper introduces the operating principle of electromagnetic force-balance sensor and electronic balance,analyzes the reason for having the error code "ERR—54" and demonstrates the repair process as well as how to calibrate the instruments after repair.
分 类 号:TH715.11[机械工程—测试计量技术及仪器]