4-氨基安替比林直接光度法测定污水中高浓度挥发酚  被引量:4

Detection of High-Content Volatile Phenol in Sewage by 4-Aminoantipyrine Direct Spectrophotometric Method

在线阅读下载全文

作  者:蔡裕丰[1] 吴春妍[1] 

机构地区:[1]启东市环境监测站,江苏启东226200

出  处:《环境科学导刊》2012年第3期85-87,共3页Environmental Science Survey

摘  要:以50.00mg/L的苯酚标准溶液配制校准曲线系列,按4-氨基安替比林直接光度法加入试剂进行显色反应,于510nm波长,用5mm比色皿测定溶液的吸光度,可将测定上限扩大到12.5mg/L。高浓度的含酚污水往往直接或稀释较少倍数就能测定。本法的检出限为0.06mg/L,显色体系可稳定60min,相对标准偏差RSD<4%,加标回收率为96.8%~102.5%,与标准法的测定结果无显著性差异。A series of the calibration curve of 50.00mg/L standard phenol solution being taken,and the reagent is added for color reaction according to 4-Aminoantipyrine direct spectrophotometric method.With a wavelength of 510mm,the light absorption rate is detected by 5mm colorimetric dish,and the detection limit could be increased to 12.5mg/L.Usually,the phenol with high concentration in the sewage can be directly detected or with little dilution.The detection limit by this method is 0.06mg/L,the color system can be maintained for 60min.The RSD is less than 4%,the recovery is between 96.8%~102.5%.The results is almost the same as that of the standard method.

关 键 词:4-氨基安替比林直接光度法 高浓度挥发酚 污水 测定 

分 类 号:X83[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象