检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中南大学信息科学与工程学院,湖南省长沙市410083 [2]东方电机有限公司,四川省德阳市618000
出 处:《中国电机工程学报》2012年第12期111-119,共9页Proceedings of the CSEE
摘 要:针对空冷水轮发电机定子绕组附加损耗的实际工程问题,从其产生的原理出发,在综合考虑了同相槽和异相槽在涡流损耗上的区别、上下层线棒股线在槽内的实际位置等多种因素影响的基础上,以一台350 MW空冷水轮发电机为例,综合运用电磁场、流场、温度场数值求解方法,对其线棒附加损耗及发热情况进行了计算分析,并与现场实测数据进行了比较。结果表明,该文方法计算精度较高,优化措施有效,对于指导大型水轮发电机定子线圈的优化设计具有良好的工程实用价值。To calculate the excessive losses of the stator coil bars in air-cooled hydro-generator,the eddy and circulating current losses and temperatures in the stator bars were investigated thoroughly.An optimal solution of electromagnetic field,fluid field,temperature field of the stator bars was presented and established using finite element method(FEM) based computational fluid dynamics(CFD)/numerical heat transfer(NHT) methods,with consideration of the factors such as the strands distribution in slots and the difference of slots of same phase and different phase.The excessive loss and temperature distribution of the stator bars were calculated and compared with the site test data from a 350?MW air-cooled large hydro generator.Results show the optimal method is accurate and effective in engineering application.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.94