摘 要:以无镍不锈钢为支架材料,以冠脉支架结构为研究对象,对其压缩和扩张过程中的力学行为和柔顺性能进行了模拟计算,研究了支架压握并扩张后的轴向回弹率、径向回弹率以及不同端部网丝宽度支架的变形行为,计算出支架的弯矩-挠度曲线及支架的柔软度。结果表明,所研究的无镍不锈钢支架具有较小的轴向与径向回弹率,在变形过程中表现出良好的弹性弯曲变形性能。The mechanical behaviors during crimping and expansion as well as the flexibility of coronary stent made of nickel-free stainless steel were simulated in this paper. The longitudinal recoil, radial recoil and the deformation behavior in crimping and expansion for different stent mesh width were investigated. The moment-deflection curve and flexibility of the stent were calculated. The results show that the nickel-free stainless steel stent has smaller longitudinal and radial recoil, and excellent flexibility in elastic bending deformation process.