检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:钱军[1] 陶梅玉[1] 孙智一[1] 顾皓亮[1]
机构地区:[1]上海市电力公司市南供电公司,上海200233
出 处:《低压电器》2011年第22期19-22,共4页Low Voltage Apparatus
摘 要:指出了光伏电站接入电网中对电压闪变产生相应影响的原因。介绍了电压闪变仪的测量原理,并在Matlab/Simulink环境下搭建了模拟电压闪变仪的仿真模型。最后,结合某光伏电站并网工程,以辐照度为变化量,以PSCAD/EMTDC为仿真平台,仿真实际光伏电站接入电网对接入点电压闪变的影响,并对仿真结果进行分析,仿真结果符合相关要求。The reason of grid-connected photovoltaic power station had effects to voltage flicker was discussed.The principle of the voltage flicker metering was described,and the analog model for the flicker metering was implemented under the environment of Matlab/Simulink according to the functions and design criterion suggested by IEC.Finally,a simulation model of the practical grid-connected photovoltaic power station in Shanghai was established in PSCAD/EMTDC,the effects on the voltage flicker of the point of integration was simulated,and the simulation results were analyzed,the simulation results meet the relevant requirements.