心脏除颤器的质量控制  被引量:4

Quality Control of Cardiac Defibrillator/Defibrillation Monitor

在线阅读下载全文

作  者:崔亮[1] 崔骊[1] 苏燕平[1] 

机构地区:[1]第四军医大学西京医院器材科,西安710032

出  处:《价值工程》2012年第13期324-325,共2页Value Engineering

摘  要:目的:通过对心脏除颤器/除颤监护仪进行质量控制检测,分析检测中发现的问题,提出解决方案,以确保该设备的安全使用。方法:采用除颤器检定仪检测,并分析失准设备的检测数据。结果:通过分析心脏除颤器/除颤监护仪的失准原因,及时维修,解决了检测中出现的问题,保障了除颤器/除颤监护仪的临床使用安全。结论:对除颤器/除颤监护仪进行质量控制非常必要,可以预防因设备失准而引起的医疗事故。Objective: Through quality control testing to the cardiac defibrillator/defibrillation monitor,we can analyze the problems of testing and propose solutions to ensure the use of safety in the clinical.Methods: Through the detector to detect the defibrillator,so we can analyze the data of misalignment equipment.Results: Trough analyzing and solving the problems in the testing,ensure the safety of the defibrillator.Conclusion: It is very necessary to test the cardiac defibrillator/defibrillation monitor that can prevent the medical accident,which caused by misalignment of medical equipment.

关 键 词:心脏除颤器 检定仪 质量控制 

分 类 号:R2[医药卫生—中医学]

 