Impact Analyses of Wind Farm on Performances of Transmission Line Relay Protection  被引量:3

Impact Analyses of Wind Farm on Performances of Transmission Line Relay Protection

在线阅读下载全文

作  者:Wang, Jin  Zhang, Baohui 

机构地区:[1] School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China

出  处:《电力系统自动化》2012年第8期148-153,共6页Automation of Electric Power Systems

基  金:supported by the Special Fund of the National Basic Research Program of China (973 Program) (No.2009CB219704)

摘  要:A simulation system for power grid with concentrated large-scale wind farm integration is established based on the electro-magnetic transient model of wind turbine equipped with doubly-fed induction generator (DFIG),which is built by real-time digital simulator (RTDS).Using the hardware communication interface of RTDS,a closed-loop testing experiment is accomplished to study the impacts of large-scale wind farms on the existing relay protection devices for wind farm outgoing transmission line.This paper points out problems existing in current relay protection devices as follows:fault phase selector can select unwanted phase due to the changes of fault features caused by special network connection of wind farms;blocking condition for distance protections needs to be re-examined due to the weak power-feed characteristics of wind farms;and power frequency parameter based relay protection devices cannot accurately operate due to the special transient voltage and current characteristics of wind farms during fault period.Results lay the foundation for improving the performances of the existing relay protection device and developing new principle relay protection.A simulation system for power grid with concentrated based on the electro-magnetic transient model of wind turbine (DFIG), which is built by real-time digital simulator (RTDS) large-scale wind farm integration is established equipped with doubly-fed induction generator Using the hardware communication interface of RTDS, a closed-loop testing experiment is accomplished to study the impacts of large-scale wind farms on the existing relay protection devices for wind farm outgoing transmission line. This paper points out problems existing in current relay protection devices as follows: fault phase selector can select unwanted phase due to the changes of fault features caused by special network connection of wind farms; blocking condition for distance protections needs to be re-examined due to the weak power-feed characteristics of wind farms; and power frequency parameter based relay protection devices cannot accurately operate due to the special transient voltage and current characteristics of wind farms during fault period. Results lay the foundation for improving the performances of the existing relay protection device and developing new principle relay protection.

关 键 词:继电保护装置 大型风电场 保护性能 输电线路 双馈风力发电机 双馈感应发电机 实时数字仿真 线路保护装置 

分 类 号:TM774[电气工程—电力系统及自动化] TM614

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象