Electroanalytical tools to investigate the divalent state of Eu(Ⅲ) and Nd(Ⅲ) ions in non-aqueous medium  被引量:1

Electroanalytical tools to investigate the divalent state of Eu(Ⅲ) and Nd(Ⅲ) ions in non-aqueous medium

在线阅读下载全文

作  者:Jignasu P Mehta Himanshu M Pandya Kahan I Pandya 

机构地区:[1]Department of Chemistry, DST-FIST sponsored Department, Mahatma Gandhi Campus, Bhavnagar University

出  处:《Journal of Rare Earths》2012年第4期392-396,共5页稀土学报(英文版)

摘  要:The divalent state of Ln(III) ions has attracted much interest because of their ability to serve isomorphously in many biological system of divalent Ca(II) ion. Therefore, present paper deals with the study of divalent state of Eu(III) and Nd(III) ions in non-aqueous medium. In present study, cyclic voltammetry and chronopotentiometry were utilized to establish the divalent state of Eu(III) and Nd(III) ions. The cyclic voltammetric technique showed two-step reduction process at cathode for both Ln(III) ions under specified experimental conditions and chronopotentiometric method also showed two different transition times (r). Looking to the shape of cyclic voltammogram we calculated het- erogeneous forward rate constant (K^fh, cm/s) and diffusion coefficient (D, cm2/s) for both ions, which suggested that sweep rate had great ef- fect on the shape of cyclic voltammogram of Eu(III) and Nd(III) ions. The result of chronopotentiometry also suggested that stable divalent states of Eu(III) and Nd(III) ions existed with chronopotentiogram with two distinct transition times. The diffusion coefficients (D, cm2/s) were calculated from Sand equation. The diffusion coefficients of both techniques were compared and the results suggested that the system at electrode surface was changing from being reversible to irreversible.The divalent state of Ln(III) ions has attracted much interest because of their ability to serve isomorphously in many biological system of divalent Ca(II) ion. Therefore, present paper deals with the study of divalent state of Eu(III) and Nd(III) ions in non-aqueous medium. In present study, cyclic voltammetry and chronopotentiometry were utilized to establish the divalent state of Eu(III) and Nd(III) ions. The cyclic voltammetric technique showed two-step reduction process at cathode for both Ln(III) ions under specified experimental conditions and chronopotentiometric method also showed two different transition times (r). Looking to the shape of cyclic voltammogram we calculated het- erogeneous forward rate constant (K^fh, cm/s) and diffusion coefficient (D, cm2/s) for both ions, which suggested that sweep rate had great ef- fect on the shape of cyclic voltammogram of Eu(III) and Nd(III) ions. The result of chronopotentiometry also suggested that stable divalent states of Eu(III) and Nd(III) ions existed with chronopotentiogram with two distinct transition times. The diffusion coefficients (D, cm2/s) were calculated from Sand equation. The diffusion coefficients of both techniques were compared and the results suggested that the system at electrode surface was changing from being reversible to irreversible.

关 键 词:Eu(IlI) and Nd(III) ions non-aqueous medium CYCLIC-VOLTAMMETRY chronopotentiomentry rare earths 

分 类 号:O614.8[理学—无机化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象