管网优化实现风机二合一改造  被引量:5

OPTIMIZATION OF PIPING NETWORK FOR REALIZING “COMBINING TWO INTO ONE” RETROFIT OF AIR FANS

在线阅读下载全文

作  者:郑金[1] 裴玉良[2] 曾剑[2] 马坤祥 丁永三 何建业[2] 

机构地区:[1]西安热工研究院有限公司,陕西西安710032 [2]国电谏壁发电厂,江苏镇江212006

出  处:《热力发电》2012年第4期72-74,共3页Thermal Power Generation

摘  要:在对国电谏壁发电厂(谏壁电厂)330MW机组引风机、增压风机运行参数测试后,提出了在不改动原引风机基础仅对管网进行改造,即将引风机出口管道与吸收塔进口连接,从而实现引风机和增压风机二合一的改造方案。改造后,降低了管网阻力,从而使厂用电下降了0.14%,风机运行效率提高使厂用电下降了0.06%,节电效果显著。The operation of induced draft (ID) fan and booster air fan for 330 MW unit in Guodian Jian- bi Power Plant has been tested,and a retrofit of "combining two into one" for ID fan and booster air fan being put forward on the basis of not changing the original ID fan and only retrofitting the original piping network, the outlet pipeline of ID fan being connected to the inlet of absorption tower. After im- plementation of retrofitting,the service power reduced 0. 14 percent point owing to decrease of resist- ance in the piping network,and the service power decreased 0. 06 percent point due to enhancing the operation efficiency of air fans. The effectiveness of electricity - saving is remarkable.

关 键 词:引风机 增压风机 风机二合一改造 管网改造 节电 

分 类 号:X773[环境科学与工程—环境工程]

 