16Mn钢恒温加载与恒载加温的力学性能试验研究  

An Experimental Research on the Dynamics of Loading after Heated and Heating after Loaded of 16Mn Steel

在线阅读下载全文

作  者:徐文毅[1] 

机构地区:[1]武警学院消防工程系,河北廊坊065000

出  处:《武警学院学报》2012年第4期87-89,共3页Journal of the Armed Police Academy

摘  要:通过对国产某型16Mn钢的恒温加载的试验研究,得到其强度折减系数随温度的升高而降低,600℃时f0.1、f0.5分别降为常温下强度的33%、50%左右;通过对该钢的恒载加温的试验研究得到其不同温度下的临界荷载水平,即在300℃、400℃、500℃、600℃时其临界荷载水平分别为0.70、0.55、0.50、0.30。为我国钢结构建筑耐火设计提供了重要的参考数据。Based on the experimental research of the loading after heated of one 16Mn steel produced in China,its strength fall coefficient will be reduced with the temperature rising.For example,f0.1 and f0.5 will drop to 33% and 50% of the normal temperature under 600 degree.Some critical load under different temperatures are obtained,which are 0.70,0.55,0.50 and 0.30 under 300,400,500 and 600 degree.This provides important basis data for fire resistance analysis of steel structure buildings.

关 键 词:16MN钢 恒温加载 恒载加温 屈服强度 强度折减系数 

分 类 号:TB301.3[一般工业技术—材料科学与工程] D631.6[政治法律—政治学]

 