600MW超临界锅炉SNCR烟气脱硝系统的启动调试  被引量:9

Selective Non-catalytic Reduction Flue De-NO_x System Start-up Commissioning Test in 600 MW Supercritical Boiler

在线阅读下载全文

作  者:杨宏民[1] 段景卫[2] 李新国[1] 

机构地区:[1]郑州电力高等专科学校,河南郑州450004 [2]西安热工研究院有限公司,陕西西安710032

出  处:《锅炉技术》2012年第3期13-19,共7页Boiler Technology

摘  要:介绍了600MW超临界锅炉SNCR烟气脱硝原理及脱硝工艺,分析了锅炉燃烧褐煤时尿素溶液流量、喷射枪的位置和机组负荷等参数对NOx排放浓度的影响,给出一般运行工况下的操作指导,初步得出不同负荷下的优化运行经验,总结了SNCR烟气脱硝工程的调试经验,并指出调试过程需要注意的问题。SNCR flue gas denitrification theory and denitrification process of 600 MW supercritical boiler is introduced, so this paper analyzes the influence on the concentration of NOx emissions of urea solution flow, spray gun position and the unit load when the boiler is burning lignite, moreover the operation guidance under the general operating conditions is given. Primary optimized operation conclusions under different load are drawn a conclusion, simultaneous summarize the SNCR flue gas denitrification commissioning experience in engineering and point out the problems that need attention when commissioning.

关 键 词:600 MW超临界锅炉 选择性非催化还原(SNCR) 烟气脱硝 尿素 调试 

分 类 号:TK229.2[动力工程及工程热物理—动力机械及工程]

 