检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:YAN Han ZHAO Lei LIU Shubin CHEN Kat WU Weihao AN Qi LENG Yongbin YI Xing YAN Yingbing LAI Longwei
机构地区:[1]State Key Laboratory of Particle Detection&Electronics,University of Science and technology of China,Hefei,230026,China [2]Anhui Key Laboratory of Physical Electronics,Department of Modern Physics,University of Science and technology of China,Hefei,230026,China [3]Shanghai Institute of Applied Physics,Chinese Academy of Sciences,Shanghai,201800,China
出 处:《Nuclear Science and Techniques》2012年第2期75-82,共8页核技术(英文)
基 金:Supported by Knowledge Innovation Program of The Chinese Academy of Sciences (KJCX2-YW-N27);the National Natural Science Foundation of China (10875119);100 Talents Program of The Chinese Academy of Sciences
摘 要:This fully digital beam position measurement instrument is designed for beam position monitoring and machine research in Shanghai Synchrotron Radiation Facility. The signals received from four position-sensitive detectors are narrow pulses with a repetition rate up to 499.654 MHz and a pulse width of around 100 ps, and their dynamic range could vary over more than 40 dB in machine research. By the employment of the under-sampling technique based on high-speed high-resolution A/D conversion, all the processing procedure is performed fully by the digital signal processing algorithms integrated in one single Field Programmable Gate Array. This system functions well in the laboratory and commissioning tests, demonstrating a position resolution (at the turn by turn rate of 694 kHz) better than 7 μm over the input amplitude range of -40 dBm to 10 dBm which is well beyond the requirement.This fully digital beam position measurement instrument is designed for beam position monitoring and machine research in Shanghai Synchrotron Radiation Facility. The signals received from four position-sensitive detectors are narrow pulses with a repetition rate up to 499.654 MHz and a pulse width of around 100 ps, and their dynamic range could vary over more than 40 dB in machine research. By the employment of the under-sampling technique based on high-speed high-resolution A/D conversion, all the processing procedure is performed fully by the digital signal processing algorithms integrated in one single Field Programmable Gate Array. This system functions well in the laboratory and commissioning tests, demonstrating a position resolution (at the turn by turn rate of 694 kHz) better than 7 Hm over the input amplitude range of-40 dBm to 10 dBm which is well beyond the reauirement.
关 键 词:上海同步辐射装置 位置测量系统 信号处理技术 光束 数字信号处理算法 现场可编程门阵列 位置敏感探测器 光源
分 类 号:TN248[电子电信—物理电子学] TL929[核科学技术—核燃料循环与材料]