检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《福建分析测试》2012年第3期27-29,共3页Fujian Analysis & Testing
摘 要:用电感耦合等离子体质谱法测定生活饮用水和地表水中的铊元素,该方法不需要进行繁琐的分离富集等预处理,也避免了光谱干扰,十分简便、快速。结果表明,该元素的检出限为7.0×10-4μg/L,加标回收率在95-102%,对质控样品平行测定6次,相对标准偏差为0.6%,完全满足对生活饮用水和地表水进行铊元素分析的要求。The Thallium was determined by using Inductively Coupled Plasma-mass Spectrometry in drinking water and source water.We need not to do many steps of separation and enrichment,and avoided spectral interference by using this method.The experiment results showed that ICP-MS method was high sensitive degree,low detection limit and it was simple,rapid,so it can help us work efficiently.The detection limit of Thallium was 7.0×10-4μg/L,the recovery standard addition was 95-102%,the RSD(n=6) was 0.6%,so this method can meet the testing requirements of the standards for water quality.
关 键 词:电感耦合等离子体质谱法 生活饮用水 地表水 铊