纯十八胺停炉保护技术在300MW亚临界机组中的应用  被引量:2

Application of Subcritical Pressure Boiler Outage Protection Method Using Pure Octadecanoic Amine

在线阅读下载全文

作  者:王仁雷 曹荣 马东伟[2] 

机构地区:[1]华电电力科学研究院,浙江杭州310030 [2]河北省电力研究院,河北石家庄050021

出  处:《发电与空调》2012年第1期18-20,共3页

摘  要:介绍了采用纯十八胺对300MW亚临界机组进行停炉保护的工艺、过程和效果。采用凝结水系统和汽包同时加药的方式,机组启动后的蒸汽品质能较快地达到合格,表明亚临界锅炉采用纯十八胺进行停炉保护过程简单、效果良好、机组启动时间缩短,有较好的经济效益。The paper introduced the technology,process and effect of pure octadecanoic amine application in the subcritical pressure boiler outage protection when the simultaneous dosing mode in the condensation water system and boiler drum was adopted,the steam quality went up to standard fast after start-up of unit.It showed that,the application effect of pure octadecanoic amine in the subcritical pressure boiler outage protection was good,the start-up time of unit could be shortened,and the economic beudfit was better.

关 键 词:纯十八胺 停炉保护 亚临界锅炉 

分 类 号:TM621.2[电气工程—电力系统及自动化]

 