检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:蓝永辉[1] 李平[1] 吴锦华[1] 王向德[1]
机构地区:[1]华南理工大学环境科学与工程学院,工业聚集区污染控制与生态修复教育部重点实验室,广东广州510006
出 处:《水处理技术》2012年第6期96-98,共3页Technology of Water Treatment
摘 要:介绍了某制药厂水解酸化+2级好氧处理肌苷生产废水的工艺特性,对调试过程中出现的污泥膨胀的原因进行了分析,并对所采取的措施及其效果进行了阐述。调试结果表明,进水SO42-质量浓度较高(>100 mg/L)或好氧池进水COD污泥负荷较低(<0.2 g/(g.d))时,好氧池会出现污泥膨胀。投加NaClO(有效氯的经验投加系数6 g/(kg.d))可以在短期内有效遏制污泥膨胀,合理控制进水SO42-含量和好氧池污泥负荷可以有效避免污泥膨胀。Introduced the character of hydrolysis acidification and two stage activated sludge process treating inosine wastewater in a pharmaceutical factory, analyzing the causes of sludge bulking during commissioning period, and discussed the measures taken in and its effect in this paper. Testing results showed that, when the sulfate concentration in the inflow was high (〉 100 rag/L) or the sludge loading of the aeration tank was low (~0.2 g/(g.d), there would be sludge bulking in the aeration tank. Adding NaC10 to the aeration tank (6 g/(kg'd) could reduce the bulking in a short term, control the sulfate concentration and the sludge loading reasonably can avoid sludge bulking effectively.