语音系统客观音质评价研究  被引量:27

Study of Objective Quality Evaluation for the Speech Systems

在线阅读下载全文

作  者:黄惠明[1] 王瑛[2] 赵思伟[1] 张知易[2] 

机构地区:[1]北京跟踪与通信技术研究所,北京100097 [2]西南通信研究所,成都610041

出  处:《电子学报》2000年第4期112-114,共3页Acta Electronica Sinica

摘  要:本文采用以谱距离为基础的LPC CD、Bark SD和Mel CD三种客观失真测度 ,对若干种语音编码设备及它们的级联系统进行了客观音质评价实验研究 .结果表明 ,这三种测度单独应用都具有较好主、客观相关性 ,它们的组合 ,给出更好的相关结果 .因此 ,可以推断 ,这些测度作为语音系统的音质评价是有一定有效性和实用性的 .Using the LPC CD,Bark SD and Mel CD distortion measures,we experimentally study the Objective Quality Eva luation of a large number of the speech systems.The result shows that each of these measures gives better correlation between objective and subjective measurement when they are used independently to those systems.Combining their results through a weighted and average way,higher correlation coefficient can be given,we can conclude that these measures have certain validity and utility to appraise the quality of speech systems.

关 键 词:语音系统 客观音质评价 语音编码 

分 类 号:TN912.3[电子电信—通信与信息系统]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象