检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李军[1] 徐扬[1] 陈宇翔[1] 吴琳[1] 朱永胜[1] 张军[1] 钱蕴秋[1] 朱霆[1] 王喜林[2] 马福成[2]
机构地区:[1]第四军医大学西京医院超声诊断科,西安710032 [2]第四军医大学西京医院,西安710032
出 处:《中华超声影像学杂志》2000年第3期161-163,共3页Chinese Journal of Ultrasonography
摘 要:目的 探讨背向散射积分 (IBS)超声组织定征判断风湿性二尖瓣病变程度的临床应用价值。方法 应用HP SONOS 2 5 0 0LE型超声诊断仪检测 3 2例二尖瓣机械瓣置换术患者和 3 0例正常人二尖瓣IBS及与主动脉后壁 (AOPW )和心包 (PC)标化值 ,以背向散射积分百分比 ( %IBS)表示 ,并与X线照片及病理结果进行对比。结果 异常组二尖瓣前叶瓣尖 (AMV )IBS[( 2 6.1± 6.1)dB]和与AOPW及PC的%IBS[( 91.6± 2 1.5 ) % ,( 68.9± 2 3 .6) % ]均高于正常对照组 [( 14 .7± 3 .9)dB ,( 5 8.6± 18.6) % ,( 3 9.3±10 .7) % ] ;钙化区IBS[( 4 0 .8± 4.5 )dB]和 %IBS[( 15 1.5± 2 8.5 ) % ,( 112 .3± 13 .6) % ]明显高于异常组 (P<0 .0 0 1)。结论 IBS对反映风湿性二尖瓣病变程度有一定的意义 ,尤其对钙化的判断有较高的敏感性。当IBS值 >3 6dB ,%IBS >12 0 % (AMV/AOPW )及 >95 % (AMV/PC)应考虑为瓣叶钙化。其敏感性为96.4% ,92 .9%和 10 0 % ,特异性为 93 .8% ,93 .8%和 90 .6%。Objective To evaluate the clinical application of integrated backscatter(IBS) tissue characterization in assessing the degree of rheumatic mitral valve lesion.Methods IBS of 32 patients who accepted mitral replacement with mechanic valves and 30 normal control subjects were analyzed with HP SONOS 2500 LE ultrasonographer.IBS of mitral valves were measured and standardized by the IBS of aortic posterior wall (AMV/AOPW) or of pericardium (AMV/PC),and expressed as %IBS .It was compared with X ray and pathological examination.Results IBS [( 26.1 ± 6.1 )dB],%IBS of AMV/AOPW [( 91.6 ± 21.5 )%] and %IBS of AMV/PC [( 68.9 ± 23.6 )%] of mitral valves tips in abnormal group were all higher than those in normal group [( 14.7 ± 3.9 )dB,( 58.6 ± 18.6 )%,( 39.3 ± 10.7 )%];furthermore,IBS and %IBS in calcificated regions [( 40.8 ± 4.5 )dB,( 151.5 ± 28.5 )%,( 112.3 ± 13.6 )%] were signifcantly higher than those in abnormal group.Localization of calcification by 2DE and IBS accorded with the results by X ray examination.Conclusions IBS are useful in assessing the degree of rheumatic mitral valves lesion,especially in detection of calcification.It is considered as calcification of valve when IBS,%IBS of AMV/AOPW and %IBS of AMV/PC is respectively more than 36 dB,120% and 95%.Their sensitivities were 96.4 %, 92.9 % and 100%,respectively,and their specificities were 93.8 %, 93.8 % and 90.6 %,respectively.
分 类 号:R541.2[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.14