检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:何列波[1] 喻李葵[1] 王晓宗[1] 马卫武[1]
机构地区:[1]中南大学能源科学与工程学院
出 处:《建筑热能通风空调》2012年第3期56-59,共4页Building Energy & Environment
摘 要:本文以某高铁站候车厅为研究对象,通过现场测试候车厅物理尺寸及相关空调参数,结合Airpak3.0专业模拟软件对候车厅冬季分层空调气流组织进行模拟,并将模拟结果与实测值进行对比分析,验证CFD模型的可靠性,最后采用PMV-PPD指标对室内舒适性进行评价,旨在为高大空间空调系统设计提供参考依据。This article based on a high-speed railway station waiting room as an illusion, the waiting room physical size and related air-conditioning parameter get by local testing, combined with Airpak3.0 simulation software to simulate stratified air-conditioning air distribution in winter of the waiting room, and analysis the simulated result and testing result by compare, verify the CFD model is feasible, Finally adopts PMV-PPD index to evaluate the indoor comfortableness, aimed to provide a reference for air-conditioning system design of the large space.
分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]