浸没式膜混凝吸附反应器处理北江水的试验研究  被引量:1

Experiment of the Beijiang River water treatment by membrane coagulation adsorption reactor

在线阅读下载全文

作  者:林显增 李冬梅[2] 叶挺进 赖日明 黄明珠 黄禹坤 

机构地区:[1]佛山市水业集团有限公司,广东佛山528000 [2]广东工业大学土木与交通工程学院,广东广州510006

出  处:《供水技术》2012年第3期1-4,共4页Water Technology

基  金:广东省省部产学研结合项目(2009B090300369);广东省科技计划项目(2009B030802020)

摘  要:采用浸没式膜混凝反应器(MCR)和浸没式膜混凝吸附反应器(MCAR)处理北江流域地表水,考察了两种工艺对污染物的去除效果及膜污染情况。结果表明,MCR与MCAR的出水浊度均低于0.100 NTU;随着混凝剂投加量的增加,MCR对有机物的去除效果逐渐提高,跨膜压差(TMP)的增加速率逐渐降低;在相同混凝剂投加量条件下,MCAR对有机物的去除效果优于MCR,且膜污染程度会进一步减缓。Comparison with the Membrane Coagulation Reactor (MCR) and the Membrane Coagulation Adsorption Reactor (MCAR) for treatment of Beijiang River surface water, the removal effects of pollutants and the contamination of membrane were investigated. The results showed that the effluent turbidity for both of MCR and MCAR were stable below 0. 100 NTU. The MCR removal effect on organic matter was increased gradually with the increase of coagulant dosage. The trans-membrane pressure (TMP) increasing rate was decreased superior to MCR under the same dosage of the gradually. The removal effect of MCAR on organics was coagulant, and the membrane contamination degree wasfurther retarded.

关 键 词:超滤膜 混凝吸附 跨膜压差 

分 类 号:TU991.2[建筑科学—市政工程]

 