检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:祝青[1,2] 苏晓 吴海军[2,4] 翟延君[1] 夏锦明[5] 布和巴特[4] 徐怡庄[2] 吴瑾光[2]
机构地区:[1]辽宁中医药大学药学院,辽宁大连116600 [2]北京大学化学与分子工程学院,北京100871 [3]山东省临沂市产品质量监督检验所,山东临沂276004 [4]内蒙古民族大学蒙医药学院,内蒙古通辽028000 [5]沈阳度太生物制药研究中心,辽宁沈阳110031
出 处:《光谱学与光谱分析》2012年第7期1790-1794,共5页Spectroscopy and Spectral Analysis
基 金:国家自然科学基金项目(50973003);国家(863计划)重大项目(2010AA03A406);科技部平台项目(2005DKA32800);北京市专利基金项目;北京大学先进技术研究院培育项目资助
摘 要:在分析复杂混合物方面原位薄层色谱-红外光谱联用有巨大潜力,二者联用能够相互取长补短,极大地提高对复杂混合物的解析能力。但因固定相自身的红外吸收能够对样品的检测造成干扰,使该方法进展缓慢。实验应用对中红外光透明的碘化银纳米微粒作为固定相制备薄层层析板,并对碘化银薄层板的层析效果及原位红外光谱检测的可行性进行了初步的研究。通过正交设计实验法优化反应条件,制备出粒径为100nm左右的碘化银颗粒;应用沉降-挥发法制备薄层层析板,实验表明该薄层板具备分离混合物的能力,且原位红外光谱检测结果表明碘化银作为固定相不干扰样品检测。In situ TLC/FTIR technique has tremendous potential in the analysis of complex mixtures. However, the progress in this technique was quite slow. The reason is that conventional stationary phase has strong absorption in FTIR spectrum and thus brings about severe interference in the detection of samples. To solve the problem, the authors propose to use AgI fine particles as stationary phase of TLC plate. The reasons are as follows: Silver iodide fine particles have no absorbance in an IR region be- tween 4 000 and 800 cm-1 , therefore, the interference caused by IR absorption of stationary phase can be removed. Moreover, silver iodide is stable and insolvable in water and organic solvents and thus it will not be destroyed by mobile phase or react with samples during the TLC separation. To improve TLC separation efficiency and quality of FTIR spectra during the TLC/FTIR a- nalysis, the size of AgI particles should be below 500 nm. We used orthogonal design approach to optimize the experimental con- dition to AgI particles so that the average size of AgI particles is around 100 nm. No absorption of impurity or adsorbed water were observed in FTIR spectrum of the AgI particles the authors used "settlement volatilization method" to prepare TLC plate without using polymeric adhesive that may bring about significant interference in FTIR analysis. Preliminary TLC experiments proved that the TLC plate using AgI fine particles as stationary phase can separate mixtures of rhodamine B and bromophenol blue successfully. Applications of silver iodide fine particles as stationary phase have bright perspective in the development of insitu TLC/FTHR analysis techniques.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.151