900W@4.5K低温超导测试系统分配阀箱结构设计与分析  被引量:3

Structural design and analysis of distribution valves box in 900W@4.5K cryogenic superconducting test facility

在线阅读下载全文

作  者:洪晨[1] 毕延芳[1] 倪清[1] 袁春燕[1] 

机构地区:[1]中国科学院等离子体物理研究所,合肥230031

出  处:《低温工程》2012年第3期36-41,51,共7页Cryogenics

摘  要:为保证结构可靠性,采用有限元分析软件ANSYS模拟分配阀箱内部真空下的变形及应力分布,并对阀箱内部冷屏结构的应力场及温度场进行分析。结果表明:采用一种由槽钢和加强块结合的加强筋形式可以有效的防止阀箱结构失效。而采用铝制冷屏加液氮冷却盘管的形式,在外界热负荷的作用下,其表面最大温度低于80 K,其变形程度随吊杆所处圆周直径的增大而减小。To avoid structural failure, a simulation evaluating the stress and deformation of distribution valve box and shields, using commercial finite elements method code ANSYS, was conducted. At the end, a rib combining two channel beams and four small cubes was designed, which can keep the chamber lid from failure. Meanwhile, the results showed that the maximum temperature on shields made of aluminum al- loys is below 80 K, and the deformation always reduces with increase of diameter.

关 键 词:分配阀箱 真空室 冷屏 结构分析 

分 类 号:TB657[一般工业技术—制冷工程]

 