拆除爆破中的大规模起爆网路的可靠性分析  被引量:14

Reliability Analysis of Large-scale Priming Circuit Used in Blasting Demolition

在线阅读下载全文

作  者:崔晓荣[1] 李战军[1] 周听清[2] 沈兆武[2] 

机构地区:[1]广东宏大爆破股份有限公司,广州510623 [2]中国科学技术大学近代力学系,合肥230027

出  处:《爆破》2012年第2期110-113,共4页Blasting

基  金:广东省科技计划资助(2006B37301005)

摘  要:通过对比分析电雷管起爆网路和非电导爆管雷管起爆网路的优缺点,认为拆除爆破中的大规模起爆网路宜采用非电导爆管网路。非电导爆管网路中,推荐方便快捷、安全可靠的纯"大把抓"网路和"大把抓"、四通复式网路,前者具有防水功能,后者网路层次分明。可靠度计算与工程实践均证明上述推荐的2种非电起爆网路,能够一次安全可靠的起爆成千上万发雷管,安全可靠性高。According to comparison of electric priming circuit and non-electric nonel tube system, the latter is suggested to be adopted in demolition blasting, especially in the ease of large detonators. The non-electric nonel tube system such as batch nodes only,or batch nodes & 4-way nodes,is used generally,because they are convenient and efficient, and the former is immune to water, while the latter is concise. The reliability analysis and engineering prac- tices both show that if the two non-electric nonel tube system discussed above are used properly, thousands of detona- tors can be primed simultaneously.

关 键 词:拆除爆破 起爆网路 可靠度分析 

分 类 号:TU746.5[建筑科学—建筑技术科学] TD235.46[矿业工程—矿井建设]

 