检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《分析测试学报》2000年第3期47-49,共3页Journal of Instrumental Analysis
基 金:陕西省自然科学基金资助项目 !(98H03)
摘 要:将在线恒电流电解产生ClO -与流动注射化学发光分析法结合 ,基于甲氨蝶呤对ClO - -鲁米诺体系化学发光的抑制作用 ,建立了测定甲氨蝶呤流动注射化学发光新方法。该法测定甲氨蝶呤质量浓度的线性范围为2×10~4×102 μg/L,检出限为1×10μg/L,相对标准偏差为2.1 %(8×10μg/L,n=9) ,已应用于片剂和针剂中甲氨蝶呤的测定。该法具有简单、快捷。A novel flow injection chemiluminescence method with electogenerated hypochlorite for the determination of methotrexate based on its inhibition of chemiluminescence from luminol-hypochlorite system is described. The linear range for methotrexate is from 2×10 to 4 ×102 μg/L and the detection limit is 1×10 μg/L. The relative standard deviation is 2.1%(n=9, c=8×10 μg/L). The proposed method is simple, rapid and sensitive, and has been successfully applied to the determination of methotrexate in pharmaceutical preparations.