检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:叶世超[1] 陈晓东[1] 李川娜[1] 候盛东 陈匡民[1]
出 处:《高校化学工程学报》2000年第2期188-193,共6页Journal of Chemical Engineering of Chinese Universities
基 金:国家自然科学基金资助项目!(29576253);四川省应用基础研究基金!(川教科-9819)。
摘 要:本文提出了振动流化床中测试水平加热管局部传热系数的新方法。该法考虑了管体温度场的非均匀性对测量结果的影响;根据管体的材质和结构,扣除了由于温度分布引起的热损失。从而采用较简单的测试手段就能够获得较准确的局部传热系数数据。将本文所得测试结果与其他研究者的测试结果作了比较,并将由局部传热系数求得的平均传热系数和实测的平均传热系数作了比较。结果表明,本文提出的测试方法可靠。A new method is developed for measurement of local heat transfer coefficients around horizontal tubes immersed in an aerated vibrated fluidized bed. The effect of temperature distribution field within the tube on the measurement was considered. Deducting the heat loss resulted from the temperature distribution from the total heat supply, the more precise local heat transfer coefficients were measured by means of the simple experimental instrument. From the comparison between the results in this work and the other researcher's data, and the comparison between average heat transfer coefficients calculated from local heat transfer coefficients and the measured average coefficients, it shows that the method proposed in this work is reliable.