检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:沈煜[1] 阮羚[1] 罗维[1] 曹蕤[2] 罗勇芬[2] 李彦明[2]
机构地区:[1]湖北省电力公司电力试验研究院,湖北武汉430077 [2]西安交通大学电气工程学院,陕西西安710049
出 处:《湖北电力》2012年第3期1-4,共4页Hubei Electric Power
摘 要:概述了目前变压器绕组变形测试诊断技术,主要分为离线测试技术和在线测试技术两大类。离线测试技术主要有低压脉冲法、短路阻抗法和频响分析法等。在线测试技术主要有超声波检测法、振动法、基于频率响应法或短路阻抗法测量变压器绕组状态等几种方法。并对上述方法的优缺点进行了比较。The present of detection and diagnosis technique of transformer winding deformation are summarized, which is usually divided into off-line and on-line testing techniques two categories. The off-line techniques mainly include Low Voltage Impulse method (LVI), Frequency Response Analysis method (FRA) and Short-circuit Reactance method (SCR). Online techniques mainly include Ultra- sonic method, Vibration method, the method based on Frequency Response Analysis and the method of Short-circuit Reactance Analysis. The merit and demerit of the methods mentioned above were also compared.