检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张红玉[1]
出 处:《建筑节能》2012年第6期8-11,共4页BUILDING ENERGY EFFICIENCY
摘 要:以天津市某绿色建筑的计算负荷为基础,通过分析不同冷热源方案全寿命周期成本,确定采用地源热泵为系统的冷热源。对地源热泵系统地源侧的年吸、释热量进行计算和分析,确保系统长期运行的稳定性。结合建筑部分负荷运行时间和地源热泵机组部分负荷性能参数,对热泵机组的选型进行分析。此外,对水系统的运行策略和室内空气品质的调控性加以分析。The building load of one green building in Tianjin was taken as the foundation, considering the life cycle cost of different heating and cooling sources, the ground source heat pump (GSHP) was chosen as the heating and cooling source of the system. The heat ab- sorption and release to the side of soil of GSHP was calculated to ensure the stability of the system for long-term operation. The unit selection of GSHP was analyzed combining the operation time of part load of the building and the part load pe~'ormance parameters of the heat pump u- nit. In addition, the operation strategy of water system and the regulation and control of indoor air quality were analyzed.
关 键 词:地源热泵 冷热量平衡 机组选型 水系统运行 室内空气品质
分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15