检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吕鑑[1] 刘硕[1,2] 廖日红[3] 刘操[3] 黄赟方[3]
机构地区:[1]北京工业大学建筑工程学院,北京100124 [2]北京市市政工程设计研究总院第三设计所,北京100082 [3]北京市水利科学研究所水环境中心,北京100048
出 处:《北京工业大学学报》2012年第8期1253-1257,共5页Journal of Beijing University of Technology
基 金:国家水体污染控制与治理科技重大专项(2009ZX07209-004);北京市科委重大专项(D07060601980802)
摘 要:采用前置反硝化曝气生物滤池和聚氨酯填料进行高质量浓度生活污水的试验,控制进水在水力负荷0.64m3/(m2.h)、回流比1∶1的条件下,研究了不同气水比下的处理效果.结果表明,该装置处理效果好且稳定,当好氧段的气水比为20∶1时,去除效果最佳,具有明显的同步硝化反硝化特征,脱氮效果明显,去除率82.96%,出水质量浓度在10 mg/L以下.对好氧段沿层取样,结果表明总氮的去除主要发生在反应器底部0~0.6 m,表明此期间也就是溶解氧在1.5~2 mg/L下同步硝化反硝化作用明显,总氮去除率保持在80%以上.通过同时监测沿层氧化还原电位(oxidation-reduction potential,ORP)的变化,确定出ORP在同步硝化反硝化过程可给出控制信号且反应灵敏稳定.可根据ORP的变化情况,优化调节曝气量,以达到高效节能的效果.The experiment of high concentration domestic sewage treatment was carried out by using predenitrifieation biological aerated filter (BAF) and polyurethane filler. Under the conditions of the hydraulic loading is 0.64 m3/( m2 .h) and reflux ratio is 1:1 , the treatment effect of different ratios of air to water was studied. Results show that the treatment effect of the device is good and stable. When the aerobic section of the gas-water ratio is 20: 1, the effect of pollutants removal is the best, with obvious features of simultaneous nitrification and denitrification, significant nitrogen removal ratio of 82.96% , and effluent concentration less than 10 mg/L. Sampling along the layer on the aerobic, results show that the total nitrogen removal mainly occurs at the bottom of the reactor between 0 and 0.6 m, demonstrating when p(DO) is between 1.5 and 2 mg/L, the simultaneous nitrification and denitrification is obvious, and the TN removal rate is remained more than 80%. By simultaneously monitoring changes in ORP values along the layer, the ORP during the simultaneous nitrification and denitrification process can send control signal and respond stably and sensitively. According to the change of ORP, the aeration can be adjusted to save energy efficiently.
关 键 词:曝气生物滤池 同步硝化反硝化 聚氨酯填料 氧化还原电位
分 类 号:X703.1[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.117.171.169