Positioning study of cervical vertebra pedicle axial line projective point by computed tomography image reconstruction  被引量:3

Positioning study of cervical vertebra pedicle axial line projective point by computed tomography image reconstruction

在线阅读下载全文

作  者:ZHANG Pei-xun XUE Feng ZHANG Dian-ying FU Zhong-guo HAN Na KOU Yu-hui JIANG Bao-guo 

机构地区:[1]Trauma and Orthopaedics Department, Peking University People'sHospital, Beijing 100044, China

出  处:《Chinese Medical Journal》2012年第14期2521-2524,共4页中华医学杂志(英文版)

摘  要:Background Safe placement of the screws is a critical aspect of trans-pedicle internal fixation, and little information on in vivo morphology of the cervical vertebrae pedicle measured with imaging methods is available. The aim of this study was to measure the dimensions of cervical vertebrae C3 to C7 and provide screw length, screw diameter and tilt angle for clinical cervical vertebra trans-pedicle internal fixation. Methods Thirty Chinese men and women underwent high-speed spiral computed tomography measurements to obtain data for C3 to C7, and the morphology of the cervical vertebra pedicles was reconstructed. Results Reconstructed computer tomography image data revealed that: (1) pedicle sponge width increased incrementally from C3 to C7, (2) pedicle depth was similar for C3 to C7, (3) pedicle angle decreased incrementally from 47.20~ to 33.76~ for' C3 to C7, and (4) pedicle point to midline distance was similar for C3 to C7. There were no statistical differences in morphological data between the right and the left side. Men had statistically larger values than women for all morphological parameters. Conclusions Reconstructed computed tomography images can provide useful data for clinical cervical vertebra trans-pedicle internal fixation. The individual measurement of cervical vertebra pedicles is recommended for safe placement of trans-vertebra pedicle screws.Background Safe placement of the screws is a critical aspect of trans-pedicle internal fixation, and little information on in vivo morphology of the cervical vertebrae pedicle measured with imaging methods is available. The aim of this study was to measure the dimensions of cervical vertebrae C3 to C7 and provide screw length, screw diameter and tilt angle for clinical cervical vertebra trans-pedicle internal fixation. Methods Thirty Chinese men and women underwent high-speed spiral computed tomography measurements to obtain data for C3 to C7, and the morphology of the cervical vertebra pedicles was reconstructed. Results Reconstructed computer tomography image data revealed that: (1) pedicle sponge width increased incrementally from C3 to C7, (2) pedicle depth was similar for C3 to C7, (3) pedicle angle decreased incrementally from 47.20~ to 33.76~ for' C3 to C7, and (4) pedicle point to midline distance was similar for C3 to C7. There were no statistical differences in morphological data between the right and the left side. Men had statistically larger values than women for all morphological parameters. Conclusions Reconstructed computed tomography images can provide useful data for clinical cervical vertebra trans-pedicle internal fixation. The individual measurement of cervical vertebra pedicles is recommended for safe placement of trans-vertebra pedicle screws.

关 键 词:pedicle of vertebral arch  internal fixation computer tomography reconstruction  imaging 

分 类 号:R687.3[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象