检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国石化北京化工研究院燕山分院,北京102500
出 处:《化工环保》2012年第4期343-346,共4页Environmental Protection of Chemical Industry
摘 要:采用Fenton试剂氧化—活性炭吸附工艺处理炼油厂循环水排污水,考察了各种因素对处理效果的影响。通过实验得出最佳处理条件为:室温,H2O2加入量600 mg/L,m(H2O2)∶m(Fe2+)=4,水样pH5.0~5.5,Fenton试剂氧化反应时间1 h,活性炭选择8~30目的无烟煤破碎炭,水样在吸附柱的停留时间约为30 min。当循环水排污水COD低于150 mg/L时,经该联合工艺处理后出水COD低于50 mg/L,达到GB8978—1996污水综合排放标准中的二级排放标准。Effluent circulation water was treated by Fenton reagent oxidation-activated carbon adsorption process and the affecting factors were investigated. The optimum conditions are as follows: room temperature, H2O2 dosage 600 mg/L, m(H2O2) : m(Fe^2+)=4, sample water pH 5-5.5, oxidation reaction time 1 h, using cracked-anthracite-based activated carbon with 8-30 mesh, water residence time in adsorption column 30 min. After the effluent circulation water with less than 150 mg/L of COD is treated, the treated water COD is below 50 mg/L, which can meet the second grade discharge standard of GB8978-- 1996.
分 类 号:X703.1[环境科学与工程—环境工程]