蒸氨塔处理高浓度剩余氨水的应用研究  被引量:6

Application of ammonia still in treating high concentration residual ammonia wastewater

在线阅读下载全文

作  者:沈连峰[1] 苗蕾[1] 宋海军[2] 于玺[1] 

机构地区:[1]河南农业大学环境工程系,郑州450002 [2]河南工程学院环境工程系,郑州451191

出  处:《给水排水》2012年第8期58-60,共3页Water & Wastewater Engineering

摘  要:焦化废水含有酚类、氰化物、氨氮等有毒有害污染物,属于高浓度难降解有机工业废水之一。以某焦化厂的蒸氨处理工程为例,根据现场调试过程中总结的调试方案及运行结果,阐述了蒸氨塔处理高浓度剩余氨水的功效、蒸氨塔系统的设备选型以及蒸氨系统的操作方法和操作条件;总结了蒸氨塔在使用过程中可能出现的问题及解决措施。The coking wastewater contains the toxic and harmful pollutants, e.g. the phenol, the cyanide, the ammonia, and so on. Therefore it is the persistent high concentration organic in- dustrial wastewater. Based on the debugging program and operation results summarized from the site debugging phase in a ammonia still treatment project of some coking plant, this paper described the effects of ammonia still in treating the persistent high concentration residual ammonia, the se- lection of the ammonia still equipment, and the operating manner and condition of the ammonia still system. The likely problems and the solution measures were also summarized.

关 键 词:焦化废水 蒸氨塔 剩余氨水 氨氮 

分 类 号:X784.031[环境科学与工程—环境工程]

 