停运工况地铁站台初期火灾烟气运动规律  被引量:1

Movement of Smoke of Early-stage Fire on Subway Platform under Out-of-service Condition

在线阅读下载全文

作  者:刘昊[1] 王燕平[2] 张昊[1] 李金龙[3] 赵金勇[2] 李宏文[1] 

机构地区:[1]中国建筑科学研究院建筑防火研究所,北京100013 [2]北京市轨道交通建设管理有限公司,北京100037 [3]北京城建设计研究总院有限责任公司,北京100037

出  处:《都市快轨交通》2012年第3期108-111,共4页Urban Rapid Rail Transit

摘  要:选用碎纸、棉绳和聚氨酯塑料试验火,在地铁站台进行火灾实体试验。在车站夜间停运条件下,对不同类型试验火源的烟气速度、温度进行监测分析,研究地铁中具有镂空格栅吊顶车站站台在停运时初期火灾烟气运动的规律,为地铁车站火灾探测研究提供技术支持。Fire experhnents were carried out on a subway platform with scraps of paper, cotton ropes as well as polyurethane plastics. With the purpose of providing technical support to the study of fire detection, authors of the paper had measured and analyzed the speeds and temperatures of the smoke generated by the fire source. At the same time movement of the smoke of early-stage fire on the platform with grid and pierced ceilings was also studied trader the condition of the subway station being out-of-service at night.

关 键 词:地铁车站 站台 停运 初期火灾 烟气运动 镂空格栅 

分 类 号:U231.96[交通运输工程—道路与铁道工程]

 