单相逆变器损耗分析与计算  被引量:4

Analysis and Calculation of Single-Phase Inverter Power Loss

在线阅读下载全文

作  者:卢兴军[1] 耿攀[1] 李庆振[1] 

机构地区:[1]上海海事大学,上海201306

出  处:《通信电源技术》2012年第4期46-51,共6页Telecom Power Technology

摘  要:提出一种逆变器损耗分析方法,并以最新的功率半导体逆变模块为例进行实例分析与计算。在对逆变模块损耗分析时,考虑了温度、驱动因素的影响,因而更为精确。通过对新型(理想)开关器件损耗计算,得出逆变器损耗的主要组成部分及影响因素;此外,还对输出滤波器损耗进行详细分析,这为以后新器件(新模块)的实际应用提供参考。A systemmatic way for analysing all losses of inverter is presented in this paper. In traditional analytical method the loss of component has always be analyzed without considering temperature and the performance of drive-circuit. However, for the latest power electronic switching devices the approximative analysis is unreasonable. Thus, more accurate analyze results can be gained if these factors are involved. The components and influencing factors of inverter losses can be obtained by experimental results of new devices. In addition, the output filter inductor losses are also analyed thoroughly. This paper gives the reference to the application of new modules.

关 键 词:电力电子 逆变器 功率损耗 

分 类 号:TM464[电气工程—电器]

 