检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:罗天保[1] 王作全[1] 沈景鹏[1] 黄健[1]
机构地区:[1]中国空气动力研究与发展中心校准测试实验室,四川绵阳621000
出 处:《中国测试》2012年第4期29-31,共3页China Measurement & Test
摘 要:风洞天平校准过程步骤多,且影响校准结果的因素多,通常采用的事后检验结果的方法难以确保校准结果数据质量。为了确保校准结果质量,运用过程控制方法,分析风洞天平校准过程,对影响校准结果数据质量的关键环节提出了具体的控制要求和控制措施,并且编制了专用校准软件程序实现对校准过程的控制,把风洞天平校准由事后检验结果改变为事前控制过程。应用结果表明:在风洞天平校准中应用过程控制方法达到了确保校准过程受控、提高校准数据质量和工作效率的预期效果。There are too many steps in the calibration process for wind tunnel balance and many factors affecting the calibration result. It is difficult to insure calibration quality by verifying the result after the event. In order to control calibration process and ensure calibration quality, statistic process-control method was applied, and the calibration process of wind tunnel balance was analyzed. Key factors that influence the calibration result were put forward. Custom calibration software was developed to control the calibration process, and the method of verifying a result after-event was changed into before-event instead. Application results demonstrated that the statistic process-control insured the controlling of calibration process and improved the calibration quality and worked efficiency.
分 类 号:V211[航空宇航科学与技术—航空宇航推进理论与工程] V211.74