方钢管混凝土柱耐火极限影响因素分析  被引量:4

PARAMETERS ANALYSIS OF THE FIRE RESISTANCE OF CONCRETE FILLED STEEL TUBULAR COLUMN WITH SQUARE SECTIONS

在线阅读下载全文

作  者:徐蕾[1] 韩林海[1] 

机构地区:[1]哈尔滨建筑大学建筑工程学院,哈尔滨150090

出  处:《工业建筑》2000年第6期24-28,共5页Industrial Construction

基  金:教育部资助优秀年轻教师基金;归国人员科研基金

摘  要:研究了方形截面钢管混凝土柱的耐火性能 ,分析了材料强度、构件截面含钢率、截面尺寸、构件长细比及荷载偏心距、保护层厚度等参数对构件耐火极限的影响。结果表明 ,材料强度、构件截面含钢率、荷载偏心距对方形截面钢管混凝土柱耐火极限的影响不大 ;截面尺寸、构件长细比对方形截面钢管混凝土柱耐火极限的影响较大 ,且截面尺寸越大 ,构件耐火极限越长 ,长细比越大 ,构件耐火极限越短。The influences of the significant parameters,such as strength of materials,steel ratio,column section dimensions,slenderness,load eccentricity,thickness of fire protection layer of a concrete filled steel tubular column with square section on its fire resistance are studied.From the results,it is indicated that the influences of strength of materials,steel ratio,load eccentricity are not significant. But the influences of column section dimensions,slenderness are greater.The fire resistance increases with increasing the column section dimensions,and decreases with increasing the slenderness.And from the results,it is shown that the fire resistance of the concrete filled square steel tubes can reach the required point by simply adding fire protection with certain depth to the column's surface.

关 键 词:方钢管混凝土柱 火灾 耐火极限 防火保护 

分 类 号:TU756.49[建筑科学—建筑技术科学]

 