检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]哈尔滨工业大学电气工程及自动化学院,黑龙江哈尔滨150001
出 处:《电力系统保护与控制》2012年第16期27-33,41,共8页Power System Protection and Control
基 金:国家自然科学基金(60972065)
摘 要:针对低压电力线载波通信可靠性低的问题,提出了人工蛛网通信网络模型,并建立了相应的数学模型。将三相配电网的MAC层转化成由多个人工蛛网组成的逻辑拓扑。详细叙述了组网过程,提出了中心节点选取算法,制定了自动路由协议。以两状态马尔科夫模型表征用户终端的工作状态,模拟实际中由于信道变化产生的终端节点通信失效。针对数据冲突率、通信流量、链路利用率等方面进行建模仿真对比实验,仿真结果表明新的组网方式及路由协议在提高电力线载波通信可靠性方面具有较大优势。Power Line Communication (PLC) over low-voltage distribution has the problem that the communication reliability is low. In order to solve this problem, a novel communication network model based on artificial cobweb is established and corresponding mathematical model is presented. The Media Access Control layer (MAC) of three-phase distribution network is turned into a logical topology which is composed of multiple artificially cobwebs. The networking process of the new model is thoroughly discussed, the algorithm of selecting the center node is proposed, and a new automatic routing protocol is established. A two-state transition Markov model is used to simulate a terminal node and the situation of communication failure because of channel changes in practice. Comparison experiments of modeling simulation are conducted in view of data conflict rate, communication flow, and link utilities, and the result has proven the new network model and routing protocol have advantage in improving communication reliability of PLC networks.
关 键 词:电力线通信 蛛网模型 组网算法 路由协议 可靠性
分 类 号:TM73[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.119.172.58