检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑学成[1] 贾俊[1] 单楠楠[1] 郭晓伟[1]
出 处:《辽宁医学杂志》2012年第4期171-172,共2页Medical Journal of Liaoning
摘 要:目的探讨人工髋关节置换股骨柄位置不佳的原因及预防方法。方法对1 420髋人工髋关节置换术病例进行分析,特别对手术操作中在股骨端开髓与扩髓方法的操作要点予以叙述。结果 56髋股骨柄位置不佳,其中41髋造成股骨炳松动,32髋出现患髋疼痛。26髋需做翻修手术,52髋开髓位置方法错误,54髋扩髓不充分。结论为减少人工髋关节置换手术后远期并发症,股骨柄置入在股骨干髓腔内的位置必须在髓腔中轴线上。开髓前要彻底剥离大粗隆内侧面软组织,以便开髓器靠近其基底部。扩髓时髓腔锉外侧面要紧靠大粗隆内侧面反复充分扩髓。Objective To discuss the reasons and prevention of femoral stem displacement (FSD) following hip ar- throplasty. Method 1 420 cases of hip replacement were analyzed for studying the FSD. Specifically, the critical procedures in opening and expanding of the femoral cavity were investigated. Resnlts Fifty six cases of FSD occurs within five years of follow up, which cause 41 cases of loosening, 32 cases of hip pain, and 26 cases of secondary re- pairing operation. Fifty two cases of inappropriate opening location and fifty four cases of inadequate expansion were identified. Conclusion In order to reduce long-term complications after hip replacement surgery, femoral stem must be positioned precisely in the central axis of femoral intramedullary canal. Before opening the femoral cavity, soft tissue attaching the inner side of the greater trochantcr need to be thoroughly removed to make the opener close to it's base,To ensure an adequate expansion of femoral cavity, the outside surface of the reamer need to be rubbed repeatedly on the inner lateral side of greater trochanter with a firm contact between each other.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.114.63