作 者:张土乔[1] 虞介泽[1] 杨德军[2] 金俊武[1]
机构地区:[1]浙江大学土木工程学系,浙江杭州310027 [2]中国矿业大学环境工程学系,江苏徐州221116
出 处:《浙江大学学报(工学版)》2012年第7期1243-1247,1261,共6页Journal of Zhejiang University:Engineering Science
基 金:国家水体污染控制与治理科技重大专项资助项目(2008ZX07421-006)
摘 要:为使水质监测点能够适合于供水管网二次加氯问题,考虑在多工况下采用I/O模型生成覆盖矩阵,建立监测点优化选址模型.为了最大化加氯点实际覆盖能力和最小化管网余氯浓度实际相对标准差,对监测点数量、加氯点数量、监测点覆盖标准和加氯点覆盖标准4个因素的优化取值进行探讨.通过实例验证表明,监测点选址模型能够找到在给定监测点数量下的最优方案.监测点覆盖标准应不大于加氯点覆盖标准,并在0.5~0.7取值,监测点数量应在布置费用约束下尽可能多,加氯点数量及布置方案应使名义覆盖率达到小于100%下的最大值.若前述条件均满足,则二次优化问题的实际相对标准差最小,且名义相对标准差和实际相对标准差的差别很小.该监测点选址模型对二次加氯问题较适用,可以减少二次加氯的总计算量.A coverage matrix and an optimal location model for monitoring stations were proposed by using the method of input/output model under multiple demand patterns in order to make water quality monito- ring stations suitable for booster chlorination in water distribution systems. Four factors which were named number of monitors, number of boosters, coverage criterion of monitoring stations, coverage criteri- on of boosters, respectively, were discussed to maximize actual coverage ability of boosters and minimize actual relative standard deviation. Case study show that optimal monitoring sites can be found by the opti- mal location model for monitoring stations under some given number of monitors. Coverage criterion of mo- nitoring stations must be no more than coverage criterion of boosters and the value can be appropriately be- tween 0. 5 and 0. 7. Number of monitoring stations must be as more as possible under the constraint about construction cost of monitors. Number of booster stations must reach maximum value of coverage ratio, which should be less than 100%. If the forgoing conditions were all satisfied, actual relative standard devi- ation of the linear least-squares problem would reach minimum, and difference of actual relative standard deviation and nominal relative standard deviation would be small. The optimal location model for monito- ring stations is suitable for booster chlorination problem, and can reduce total amount of calculation about the booster chlorination problem.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.190.239.193