检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:沈化荣[1,2] 卢小琳[2] 高培伟[2] 张辉[2] 王珐玮 夏江涛[1]
机构地区:[1]淮阴工学院土木工程系,江苏淮安223001 [2]南京航空航天大学材料学院,江苏南京210016 [3]吉林省交通科学研究所,吉林长春130012
出 处:《混凝土》2012年第8期8-9,13,共3页Concrete
基 金:西部交通项目(2009CB01);"863"国家高新技术项目(2009AA03Z508)
摘 要:参照CDF盐冻试验标准研究了气泡间距系数对水泥混凝土抗盐冻性能,研究结果表明:混凝土抗盐冻性能随气泡间距系数减小而迅速提高,并具有很好的相关性;当气泡间距系数在0.2 mm以下时,混凝土剥蚀量的下降幅度随气泡间距系数减小而减缓,控制气泡间距系数可很好地改善混凝土的抗盐冻性能。The frost-salt resistances of concrete were investigated according to the CDF method effects of air void systems introduced by differ- ent air entraining agent.The results showed that the frost-salt resistance of concrete increased with the decreasing of spacing factor and increasing of air content.The speed of frost-salt scaling of concrete was reduced when the spacing factor less than 0.200 mm.The results also showed that the frost-salt resistance of concrete of different surface exist difference.The frost-salt resistance of concrete can improve by controlling of the spacing factor not the air content.