基于智能终端的用电回路运行状态异常监测  被引量:2

Electricity Loop Running State Monitoring Based on Intelligent Terminal

在线阅读下载全文

作  者:程瑛[1] 陈锐民[2] 方源[1] 方彦军[1] 

机构地区:[1]武汉大学自动化系,武汉430072 [2]广东电网公司电力科学研究院,广州510080

出  处:《华东电力》2012年第8期1362-1365,共4页East China Electric Power

基  金:国家自然科学基金资助项目(61170024);中国博士后科学基金项目(2011M501234)~~

摘  要:针对电能质量的评估问题,提出一种基于智能终端测量结果的实时用电监测技术。研究电压和电流异常情况,分析其工作原理和异常判断条件,并对电压缺相、电压逆相序、电流反极性及电流不平衡等情况进行研究,详细阐述监测原理,提出软件流程图并给出相应的程序伪代码,对电能质量监测技术的发展有一定的参考价值。Aiming at the power quality evaluation, this paper proposes a real-time power consumption monitoring tech- nology based on intelligent terminal measurements. As for the research on abnormal voltage and current, the principle and abnormal condition judgment were analyzed; As for the study on voltage phase fault, voltage reverse phase se- quence, current reverse polarity and current imbalance, the monitoring principle was elaborated. Finally, this re- search presents software flow chart and the corresponding pseudocode, providing some valuable reference to the future development of electric power quality monitoring technology.

关 键 词:电能质量 智能终端 监测 

分 类 号:TM933[电气工程—电力电子与电力传动]

 