检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《Chinese Journal of Chemistry》2012年第8期1851-1856,共6页中国化学(英文版)
摘 要:A new photoelectrochemical method for the determination of glucose based on the photoelectrochemical effect of poly(thionine) photoelectrode to hydrogen peroxide (H202) was reported. The H2Oz-sensitive photoelectrode was fabricated by electropolymerizing thionine on the surface of ITO electrode. And then glucose oxidase was immobilized on the photoelectrode via the aid of chitosan enwrapping, forming an enzyme-modified photoelectrode. The photoelectrode was employed as an electron acceptor; H2O2 from the catalytic reaction of enzyme was employed as an electron donor, developing an analytical method of glucose without hydrogen peroxidase. In the paper, the pho- toelectrochemical effects of photoelectrode to H202 and glucose were studied. The effects of the bias voltage and the electrolyte pH on the photocurrent were investigated. The linear response of glucose concentrations ranged from 0.05 to 2.00 mmol/L was obtained with a detection limit of 22.0 μmol/L and sensitivity of 73.2 nA/(mmol·L-1). The applied feasibility of method was acknowledged through monitoring the glucose in practical samples.A new photoelectrochemical method for the determination of glucose based on the photoelectrochemical effect of poly(thionine) photoelectrode to hydrogen peroxide (H202) was reported. The H2Oz-sensitive photoelectrode was fabricated by electropolymerizing thionine on the surface of ITO electrode. And then glucose oxidase was immobilized on the photoelectrode via the aid of chitosan enwrapping, forming an enzyme-modified photoelectrode. The photoelectrode was employed as an electron acceptor; H2O2 from the catalytic reaction of enzyme was employed as an electron donor, developing an analytical method of glucose without hydrogen peroxidase. In the paper, the pho- toelectrochemical effects of photoelectrode to H202 and glucose were studied. The effects of the bias voltage and the electrolyte pH on the photocurrent were investigated. The linear response of glucose concentrations ranged from 0.05 to 2.00 mmol/L was obtained with a detection limit of 22.0 μmol/L and sensitivity of 73.2 nA/(mmol·L-1). The applied feasibility of method was acknowledged through monitoring the glucose in practical samples.
关 键 词:photoelectrochemical analysis PHOTOELECTRODE GLUCOSE THIONINE
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.28.166