摘 要:直流母线电压的稳定性是PWM整流器的一个重要指标。在电网电压不平衡且(或)含有低次电力谐波时,传统的控制方法不能消除直流母线电压的抖动。为解决这一问题,首先深入分析了电网电压不平衡且含有5次、7次谐波分量对电压源型PWM整流器的直流母线电压稳定性的影响;进而提出了一种基于比例积分-谐振(PI-R)的控制策略,并详细分析了电流控制指令计算和PI-R控制器的设计方案。1 MW PWM整流器的仿真结果表明,所提出的控制策略能显著抑制直流母线电压的波动,并提高系统的安全运行性能。The stability of the DC-link voltage is a main target of the grid-connected PWM rectifier. When the grid voltage is unbalanced and (or)harmonically distorted, the conventional control strategy can't eliminate the pulsation of DC-link voltage. In order to solve this problem, Firstly, the effect of unbalanced and 5th and 7th harmonics to the VSR was analyzed;and then, an approach based on PI-R controller was proposed, with detail calculation of the current references and designation of current controller. Simulation results of a 1 MW VSR indicate that the proposed control strategy can significantly reduce the DC-link voltage pulsation, enhance the operation of the DC-link capacitor and the associated load safely.
关 键 词:电压源型PWM整流器 谐波畸变 比例积分-谐振控制器 直流母线电压
分 类 号:TM712[电气工程—电力系统及自动化]