THEORETICAL AND EXPERIMENTAL STUDIES OF THE FLARING GATE PIER ON THE SURFACE SPILLWAY IN A HIGH-ARCH DAM  被引量:11

THEORETICAL AND EXPERIMENTAL STUDIES OF THE FLARING GATE PIER ON THE SURFACE SPILLWAY IN A HIGH-ARCH DAM

在线阅读下载全文

作  者:LI Nai-wen LIU Chao DENG Jun ZHANG Xiao-zhe 

机构地区:[1]State Key Laboratory of Hydraulics and Mountain River Engineering, Sichuan University, Chengdu 610065,China [2]College of Hydraulic and Hydroelectric Engineering, Sichuan University, Chengdu 610065, China

出  处:《Journal of Hydrodynamics》2012年第4期496-505,共10页水动力学研究与进展B辑(英文版)

基  金:the National Natural Science Foundation of China (Grant Nos. 50909067, 51009102);the Program for New Century Excellent Talents in University (Grant No. 2011SCU-NCET-10-0589)

摘  要:The experimental studies of the flaring gate pier applied on the surface spillway in a high-arch dam show that a shock-wave will appear when the pattern of the flow is kept as super-critical. Meanwhile, the water depth at the outlet increases significantly, the flow moves downward in different directions, and the plunging jet is in a narrow and long shape, with a full longitudinal diffusion. In addition, the variation of the flaring gate pier design parameters affects little the discharge capacity of the surface spillway, these parameters including the contraction ratio fl, the contraction angle c~ and the spillway chute angle O. The pressure on the bottom of the spillway increases along the way and reaches the maximum before the outlet, and then decreases rapidly. Due to the flow impacting, the pressure on both sidewalls increases abruptly at the turning line of the flaring gate pier. To see the characteristics of the flow in the flaring gate pier, a simple calculation method is suggested based on the conversation of energy and mass, and the calculation methods for the jet trajectory and the horizontal length in air are also proposed. The results are found in good agreement with experimental data.The experimental studies of the flaring gate pier applied on the surface spillway in a high-arch dam show that a shock-wave will appear when the pattern of the flow is kept as super-critical. Meanwhile, the water depth at the outlet increases significantly, the flow moves downward in different directions, and the plunging jet is in a narrow and long shape, with a full longitudinal diffusion. In addition, the variation of the flaring gate pier design parameters affects little the discharge capacity of the surface spillway, these parameters including the contraction ratio fl, the contraction angle c~ and the spillway chute angle O. The pressure on the bottom of the spillway increases along the way and reaches the maximum before the outlet, and then decreases rapidly. Due to the flow impacting, the pressure on both sidewalls increases abruptly at the turning line of the flaring gate pier. To see the characteristics of the flow in the flaring gate pier, a simple calculation method is suggested based on the conversation of energy and mass, and the calculation methods for the jet trajectory and the horizontal length in air are also proposed. The results are found in good agreement with experimental data.

关 键 词:high-arch dam flood discharge and energy dissipation flaring gate pier hydraulic calculation jet trajectory distance 

分 类 号:TV651.1[水利工程—水利水电工程] O4-33[理学—物理]

 