微波辅助Fenton处理含酚炼油废水的试验研究  被引量:4

Experiments on the treatment of phenol-containing oil-refining wastewater by microwave-assisted Fenton reagent oxidation technology

在线阅读下载全文

作  者:赵西往[1] 张永刚[2] 陈立群[2] 李勇[3] 王冀生[1] 

机构地区:[1]中海油天津化工研究设计院,天津300131 [2]天津工业大学环境与化学工程学院,天津300160 [3]河北峰煤焦化有限公司,河北邯郸056202

出  处:《工业水处理》2012年第9期62-65,共4页Industrial Water Treatment

摘  要:采用微波辅助Fenton工艺处理某炼油厂含苯酚废水,通过实验研究了敏化剂种类、微波功率、微波辐射时间等因素对苯酚去除效果的影响,确定了微波辅助Fenton试剂催化氧化处理高浓度苯酚废水的最佳工艺条件。对于2 000 mg/L的苯酚废水,Fe2+用量为1 600 mg/L,H2O2投加质量分数为0.3%,活性炭投加量为10 g/L,微波功率为13.2 W,微波辐射时间5 min时,苯酚去除率可达到80%以上,明显优于单独活性炭微波和单独Fenton试剂氧化的处理效果。The influences of the varieties of microwave sensitizers, microwave power and microwave irradiation time on the removing efficiency of phenol from phenol-containing wastewater in a refinery have been studied through experiments. The best technological conditions of microwave-assisted Fenton reagent catalytic oxidation technology for treating highly concentrated phenol-containing wastewater are ascertained. For the phenol wastewater with the mass concentration of 2 000 mg/L, the removing rate of phenol could reach 80%, when the dosage of Fe2+ is 1 600 mg/L, H2O2 is 0.3%, active carbon is 10 g/L, microwave power is 13.2 W and the time of microwave radiation is 5 min. The experiment results show that it is obviously much better than using active carbon-microwave alone and Fenton reagent oxidation alone.

关 键 词:含酚废水 微波辐射 炼油废水 

分 类 号:X703[环境科学与工程—环境工程]

 