考虑振动区的水电机组组合优化研究  被引量:11

Unit Commitment of Hydropower Station Considering Vibration Zone

在线阅读下载全文

作  者:李文武[1] 郑俊[1] 吴稀西[1] 曹茅 

机构地区:[1]三峡大学电气与新能源学院,湖北宜昌443002 [2]湖北黄龙滩水力发电厂,湖北十堰442005

出  处:《水电能源科学》2012年第9期122-124,216,共4页Water Resources and Power

基  金:湖北省自然科学基金资助项目(50579019);湖北省教育厅自然科学研究基金资助项目(Q20091307)

摘  要:水轮机在实际运行中存在振动区,水电机组需避免在此区间运行。为此建立了考虑水轮机振动区的水电机组组合优化的发电量最大数学模型,利用分支定界法确定了机组的运行区间,并采用动态规划方法求最优解。实例应用结果表明,分支定界与动态规划相结合的方法适合于水电机组的实际运行情况,且提高了求解精度。Hydro turbines may be running in the vibration zone, so hydropower units are forbidden to run in this zone. The mathematical model of hydropower unit commitment with maximum electricity is established by considering vibration zone. The branch and bound method is used to determine operating range of generating set and the optimal solution are obtained by using dynamic programming. The example results show that the proposed method is fitted for solving hydropower unit commitment and improves the solution precision.

关 键 词:水电机组组合优化 振动区 分支定界 动态规划 

分 类 号:TV734[水利工程—水利水电工程]

 