微通道板像增强器动态范围测试技术研究  被引量:4

Research on Dynamic Range Testing for Image Intensifier With Microchannel Plate

在线阅读下载全文

作  者:拜晓锋[1,2] 尹雷[1,2] 程宏昌[1,2] 胡文[1,2] 贺英萍[1,2] 

机构地区:[1]微光夜视技术重点实验室,陕西西安710065 [2]北方夜视科技集团有限公司,云南昆明650223

出  处:《光学与光电技术》2012年第5期21-23,共3页Optics & Optoelectronic Technology

摘  要:研究了微通道板像增强器动态范围特性,分别分析了以亮度增益、信噪比和分辨力等参数作为判断微通道板像增强器动态范围依据的可行性,形成了以分辨力和输出亮度为评判依据的微通道板像增强器动态范围测试方法,搭建了相应的动态范围测量装置,并对测量装置的组成部分进行了限制设计。对微通道板像增强器动态范围测试装置的分析显示:建立的测量装置可以实现10-5~103 lx的较宽动态范围测量,能够满足微通道板像增强器动态范围测试的要求。Feasibility of determining the dynamic range of image intensifier based on resolution, luminance gain and signal to noise ratio has been analyzed respectively. Testing method of dynamic range, which is based on the limited resolution and output brightness, has been formed finally by researching and analyzing the characteristic of dynamic range for image intensi- fier with microchannel plate, and the test set has been funded, in which some parts have been restrained technically. Analy- zing result shows that wider dynamic range with 10-5 lx--103 lx can be tested and dynamic range test for image intensifier with microchanneI plate can be satisfied in dynamic range measurement setup.

关 键 词:像增强器 动态范围 微通道板 亮度增益 信噪比 极限分辨力 

分 类 号:TN223[电子电信—物理电子学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象