改进型硅胶-水吸附制冷机的实验研究  被引量:2

Experimental Investigation of an Improved Silica Gel-Water Adsorption Chiller

在线阅读下载全文

作  者:余楠 王如竹 陆紫生 

机构地区:[1]上海交通学大学制冷与低温研究所,上海200240

出  处:《工程热物理学报》2012年第10期1663-1666,共4页Journal of Engineering Thermophysics

基  金:国家自然科学基金国际合作重点项目(No.51020105010)

摘  要:针对改进型硅胶水吸附式制冷机进行了实验研究,在热水进口温度为84℃,冷冻水进口温度为21℃,冷却水进口温度为30℃,回质时间为90 s的工况下,本文研制的改进型制冷机获得了14.0 kW的制冷功率和0.40的COP,制冷功率比之前提高了60%;引入温度参数这一无量纲变量建立起本机组制冷性能的拟合方程,从而方便地预测出制冷机在所有工况下的制冷功率和COP。An improved silica gel-water adsorption chiller was experimentally investigated. When the hot water inlet temperature, cooling water inlet temperature, and chilled water outlet temperature were 84.0℃, 30℃, and 21℃ respectively, the cooling capacity was 14.0 kW, improved by 60% and the COP was 0.40. A dimensionless variable named reduced temperature is introduced to build the performance fitted equations, which makes predicting the cooling capacity and COP of the chiller at all conditions easily.

关 键 词:硅胶  吸附制冷 温度系数 

分 类 号:TB6[一般工业技术—制冷工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象