检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海交通学大学制冷与低温研究所,上海200240
出 处:《工程热物理学报》2012年第10期1663-1666,共4页Journal of Engineering Thermophysics
基 金:国家自然科学基金国际合作重点项目(No.51020105010)
摘 要:针对改进型硅胶水吸附式制冷机进行了实验研究,在热水进口温度为84℃,冷冻水进口温度为21℃,冷却水进口温度为30℃,回质时间为90 s的工况下,本文研制的改进型制冷机获得了14.0 kW的制冷功率和0.40的COP,制冷功率比之前提高了60%;引入温度参数这一无量纲变量建立起本机组制冷性能的拟合方程,从而方便地预测出制冷机在所有工况下的制冷功率和COP。An improved silica gel-water adsorption chiller was experimentally investigated. When the hot water inlet temperature, cooling water inlet temperature, and chilled water outlet temperature were 84.0℃, 30℃, and 21℃ respectively, the cooling capacity was 14.0 kW, improved by 60% and the COP was 0.40. A dimensionless variable named reduced temperature is introduced to build the performance fitted equations, which makes predicting the cooling capacity and COP of the chiller at all conditions easily.
分 类 号:TB6[一般工业技术—制冷工程]